ELECTRICAL SPECIFICATIONS
THEORY OF OPERATION
Parameter
Designation
Min.
Typical
Max.
Units
Notes
The FCTN-WALL-*** module combines
POWER SECTION
the popular Linx LR Series receiver with a
Operating Voltage
Relay Rating
V CC
100
110
120
VAC
mA
2
decoder and high quality switching relay.
When transmitted data is received, the
Tungsten or Resistive load
Electronic Ballast
Power
Power
Power
Relay Cycle Life
1x10 5
15.0
5.0
1,800
1
15
A
A
W
HP
FLA
1
1
1
1
1
data is presented to the decoder. The
decoder detects the logic states of the DIP
switch address lines, and if these match
the address settings of the encoder, the
decoder’s outputs are set to replicate the
state of the encoder’s inputs. In the AC
B u tton 1
B u tton 2
B u tton 3
B u tton 4
A0 = Addr. 1
A1 = Addr. 2
A2 = Addr. 3
A 3 = Addr. 4
OFF ON
RECEIVER SECTION
Function Module, the data lines are also
Receive Frequency Range:
F C
compared to the settings of four control dip
FCTN-WALL-315
FCTN-WALL-418
315
418
MHz
MHz
switches that determine which transmitter
buttons or data lines will be accepted. The
Figure 3: Module DIP Switches
FCTN-WALL-433
Center Frequency Accuracy
Receiver Sensitivity
Noise Bandwidth
N 3dB
-50
-106
433. 9 2
-112
280
+50
-118
MHz
kHz
dBm
kHz
1
relationship is shown in the adjacent chart.
If the DIP switch labeled Button 1 is turned
on, then when data line D6 on the decoder
goes high, the AC Function Module will
DIP Switch Data Lines
Button Off On
1 D7 D6
ENVIRONMENTAL
activate and apply power to the output.
2 D5 D4
Operating Temperature Range
Storage Temperature Range
-30
-45
+50
+85
° C
° C
1
1
When line D7 goes high, the module will
turn off. As long as the other button
switches are turned off, the module will
3 D3 D2
4 D1 D0
Table 1: FCTN-WALL-*** Specifications
Notes
1. Characterized, but not tested.
2. Minumum relay load of any approved type
AC FUNCTION MODULE FEATURES
2
ignore all of the other data lines. If multiple DIP switches are turned on, then the
module will be controlled by multiple buttons or data lines. For example, if
switches 1 and 2 are on, then lines D6 and D4 will switch the AC Function
Modules output on and lines D7 and D5 will turn it off.
SETTING MODULE ADDRESS
The AC Function Module provides a total of sixteen unique address settings.
Address selection is made via the bottom four DIP switches on the module. In
order for the encoded commands sent by the transmitter to be recognized, the
address settings of the transmitter and receiver must match exactly.
CREATING UNIQUE GROUPS
The four control DIP switches can be used to create distinct groups of AC
Function Modules that can all be operated by a single command unit. For
1
4
example, any number of AC Function Modules can be set to a single address
and be controlled by one of the button pairs (ON / OFF) on a command unit. You
can also set up different banks using up to sixteen AC Function Modules, each
set to a different address. Please read the Contention Considerations section
when using multiple transmitters in close proximity.
3
1. Up to 1,800 watts switched AC power outlet
2. Standard 3-prong plug can be used with wall outlet, power strip, or extension cord
3. Multi-position antenna for optimum reception
4. Control DIP Switches used to set address and command button
Figure 2: FCTN-WALL-*** Features
Page 2
EQUIPMENT CONNECTION
Each AC Function Module is designed to switch AC loads of up to 1,800 watts.
Plug the AC Function Module in, then plug the equipment to be switched into the
receptacle on the face of the unit. More than one device can be connected with
the addition of a power strip; however, the total draw of all connected equipment
must never exceed the unit’s 1,800W rating.
Page 3
相关PDF资料
FCX11362_IRIS LENS FOR CREE XP-E/G
FDA032N08 MOSFET N-CH 75V 120A TO-3P
FDA15N65 MOSFET N-CH 650V 16A TO-3PN
FDA16N50_F109 MOSFET N-CH 500V 16.5A TO-3P
FDA18N50 MOSFET N-CH 500V 19A TO-3P
FDA20N50_F109 MOSFET N-CH 500V 22A TO-3P
FDA20N50 MOSFET N-CH 500V 22A TO-3P
FDA24N40F MOSFET N-CH 400V 23A TO-3PN
相关代理商/技术参数
FCTPF10PKE 制造商:Distributed By MCM 功能描述:Slim Pink iPad Case
FCTS73-05N 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE ADHESIVE 0.85W/M.K 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE, ADHESIVE, 0.85W/M.K 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE, ADHESIVE, 0.85W/M.K, Thickness:0.05mm, Conductive Material:Acrylic 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE, ADHESIVE, 0.85W/M.K, Thickness:0.05mm, Conductive Material:Acrylic Polymer, Thermal Conductivity:0.85W/m.K, External Length:305mm, External Width:305mm, Series:FCT73, SVHC:No SVHC (19-Dec-2012), Isolation Vo , RoHS Compliant: Yes
FCTS73-10N 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE ADHESIVE 0.85W/ 制造商:AMEC THERMASOL 功能描述:THERMAL TAPE, ADHESIVE, 0.85W/M.K; Thickness:0.10mm; Conductive Material:Acrylic Polymer; Thermal Conductivity:0.85W/m.K; External Length:300mm; External Width:300mm; Series:FCT73; SVHC:No SVHC (19-Dec-2012); Isolation V ;RoHS Compliant: Yes
FCU-010M002 功能描述:I/O 连接器 10GIG ETHERNET CX4 MODULE XENPAK RoHS:否 制造商:Hirose Connector 产品:Plugs 系列:DH 端口数量: 位置/触点数量:51 节距:1 mm 触点电镀: 触点材料: 型式:Male 电流额定值:0.5 A 安装风格:Cable 端接类型:IDC 颜色: 安装角:
FCU-022M101 功能描述:I/O 连接器 10GIG ETHERNET CX4 MODULE EAS X2 MSA RoHS:否 制造商:Hirose Connector 产品:Plugs 系列:DH 端口数量: 位置/触点数量:51 节距:1 mm 触点电镀: 触点材料: 型式:Male 电流额定值:0.5 A 安装风格:Cable 端接类型:IDC 颜色: 安装角:
FCU10A30 制造商:NIEC 制造商全称:Nihon Inter Electronics Corporation 功能描述:FRD - Low Forward Voltage Drop
FCU10A60 制造商:NIEC 制造商全称:Nihon Inter Electronics Corporation 功能描述:FRD FOR POWER FACTOR IMPROVEMENT HIGH FREQUENCY RECTIFICATION
FCU10B60 制造商:NIEC 制造商全称:Nihon Inter Electronics Corporation 功能描述:FRD - For Power Factor Improvement High Frequency Recification